XLPE
+
  • XLPE

XLPE

Category:

Cross-linked polyethylene power cable insulation material is produced according to a fully automated closed extrusiongranulation system and mature post-absorption process route.
  • Commodity name: XLPE

Description

Cross-linked polyethylene power cable insulation material is produced according to a fully automated closed extrusiongranulation system and mature post-absorption process route.

 

Product Application

Dominates insulation for medium/high-voltage power cables.ss.

Automotive Cables

High voltage Cable

Wire and Cable

 

Performance

Polyethylene (PE) cross-linking technology is one of the most important means of improving its material properties. After crosslinking modified PE can make its performance has been greatly improved, not only significantly improve the PE mechanical properties, environmental stress cracking resistance, chemical resistance, corrosion resistance, creep resistance and electrical properties and other comprehensive performance, but also very obviously improve the temperature resistance level, can make the PE heat-resistant temperature from 70℃ to more than 100℃, thus greatly broadening the application areas of PE.

 

WANHUA XLPE

Item

Test Condition

Unit

Standrad

4201
Rated Voltage 12KV
(Um=17.5KV)

4201C
Rated Voltage
up to 69KV
(Um=72.5KV)

4201S
Rated Voltage
up to 161KV
(Um=170KV)

4201SC
Rated Voltage
up to 230KV
(Um=245KV)

4201EHV
Rated Voltage
> 230KV
(Um=550KV)

Density

-

kg/m³

ISO 1872-2
ISO 1183

922

922

922

922

922

Bulk density

-

kg/m³

-

500-600

500-600

500-600

500-600

500-600

Alcohol wash residue

-

ppm

TMW

<2000

<2000

<1500

<1000

<1000

MFR

190℃/2.16kg

g/10min

ISO 1133

2

2

2

2

2

Elongation rate

200mm/min

%

GB/T 1040.1
GB/T 1040.2

>500

>500

>500

>500

>500

Tensile strenth

200mm/min

MPa

GB/T 1040.1
GB/T 1040.2

>17

>17

>17

>17

>17

Tensile change rate after aging

200mm/min
168h 135℃

%

GB/T 2951.12

±20

±20

±20

±20

±20

Hot extension test load elongation

200±3℃
0.2Mpa 15min

%

GB/T 2951.21

≤75

≤75

≤75

≤75

≤75

Hot extension test permanent deformation rate

200±3℃
0.2Mpa 15min

%

GB/T 2951.21

≤5

≤5

≤5

≤5

≤5

Moisture content

Karl Fischer
titration method

ppm

SH/T 1770

≤200

≤200

≤200

≤200

≤200

Electrical properties

 

 

 

 

 

 

 

 

Relative permittivity

50Hz 23℃

-

GB/T 1409

≤2.35

≤2.35

≤2.35

≤2.35

≤2.35

Dielectric loss factor

50Hz 23℃

-

GB/T 1409

≤5*10-4

≤5*10-4

≤5*10-4

≤5*10-4

≤5*10-4

Volume resistivity

1KV/mm 23℃

Ω*m

GB/T 1410

≥1.0*1014

≥1.0*1014

≥1.0*1014

≥1.0*1014

≥1.0*1014

 

Item

Test Condition

Unit

Standrad

4205C
Rated Voltage 69KV
(Um=72.5KV)

4205S
Rated Voltage
161KV
(Um=170KV)

4205SC
Rated Voltage
230KV
(Um=245KV)

4205EHV
Rated Voltage
>230KV
(Um=550KV)

Density

-

g/m³

ISO 1033.1

≤1.15

≤1.15

≤1.15

≤1.15

Elongation rate

200mm/min

%

GB/T 1040

>150

>150

>150

>180

Tensile strenth

200mm/min

MPa

GB/T 1040

>15

>15

>15

>15

Tensile change rate after aging

168h 135℃

%

GB/T 2951.12

±20

±20

±20

±20

Hot extension test load elongation

200mm/min
168h 135℃

%

GB/T 2951.5

<100

<80

<60

<60

Hot extension test permanent deformation rate

200℃
0.2Mpa

%

GB/T 2951.5

<10

<10

<10

<10

Electrical properties

200℃
0.2Mpa

 

 

 

 

 

 

Semiconductor resistivity

-

Ω*m

GB/T 3048.3

<50

<50

<50

<50

90 degree semiconductor resistivity

-

Ω*m

GB/T 3048.3

<1000

<500

<300

<200

Keyword:

XLPE

Get A Quote

Note: Please leave your email address, our professionals will contact you as soon as possible!